Can I use my US-bought HP LaserJet 2100se in China?
I own an HP LaserJet 2100se (C4138A) purchased in the US. I want to
take the printer and work in mainland China for a while. **************************** Electrical Specs of HP LaseJet 2100 (from the User's Manual) 100-127V (+/- 10%) 50/60Hz (+/- 2Hz) However the User's Manual has no electrical description for HP LaserJet 2100se I own. HP LaserJet official support site: http://h20000.www2.hp.com/bizsupport...&lang=en&cc=us **************************** Basing on the above electrical specs, I suspect I can't use the printer like I use it in the States. I e-mailed HP, and expectedly got reply saying that due to regulatory laws they can't recommend use of printer with 110V in a non-110V country and vice vera. I am inclined to get a good voltage transformer for use of the printer in China. I want to know is whethere it is practically possible from an end user's perspective. Voltage transformer such as one at this site: http://www.voltageconverters.com/vol...onverters.html Questions: 1. Can anyone kindly advise if this is feasible? 2. Is there anything else other than voltage and frequency differences I have overlooked? Thanks for your time and help!!! |
#2
|
|||
|
|||
Can I use my US-bought HP LaserJet 2100se in China?
Sorry forgot to mention this...
China uses 220V voltage and 50Hz frequency in contrast to 120V and 60Hz in the US. |
#3
|
|||
|
|||
Can I use my US-bought HP LaserJet 2100se in China?
You want to connect the 120V printer to a 220V power source, some
modern power units being the switch mode type will allow you to do this - but you need to be certain, otherwise damage will be done. The only way to be certain is to get a voltage converter, the modern types usually contains a electronic circuit to do this, other's it's just a step-up transformer, these accepts the 120V input and out comes the 220V supply, but it does need to be adequately rated for the amount of power (Wattage) drawn. The frequency rating I think can be ignored, usually 50-60 Hz being typical, the plus minus 2Hz stated seems a little mean, it's usually plus or minus 20Hz, note Hz and c/s or cps are exactly the same thing where we are concerened here. The transformer types are the simplist but may be bulky, because of today's technology the switch-mode or modern type are usually much smaller and much lighter in weight. A Laser will take a fair amount of power, I guess around 300 Watts, note the word guess... this is something you need to work out before purchase. Voltage times the Current = the power in watts or if you want to know the current it's the power divided by the voltage = current in Amps, these can usually be taken (and calculated if need be) from the power label sticker on the printer. Davy |
#4
|
|||
|
|||
Can I use my US-bought HP LaserJet 2100se in China?
"7palmtree" wrote:
I own an HP LaserJet 2100se (C4138A) purchased in the US. I want to take the printer and work in mainland China for a while. **************************** Electrical Specs of HP LaseJet 2100 (from the User's Manual) 100-127V (+/- 10%) 50/60Hz (+/- 2Hz) However the User's Manual has no electrical description for HP LaserJet 2100se I own. HP LaserJet official support site: http://h20000.www2.hp.com/bizsupport...&lang=en&cc=us **************************** Basing on the above electrical specs, I suspect I can't use the printer like I use it in the States. I e-mailed HP, and expectedly got reply saying that due to regulatory laws they can't recommend use of printer with 110V in a non-110V country and vice vera. I am inclined to get a good voltage transformer for use of the printer in China. I want to know is whethere it is practically possible from an end user's perspective. Voltage transformer such as one at this site: http://www.voltageconverters.com/vol...onverters.html Questions: 1. Can anyone kindly advise if this is feasible? 2. Is there anything else other than voltage and frequency differences I have overlooked? Thanks for your time and help!!! The specs clearly state 50/60Hz. So if China is 220v 50Hz a power converter or transformer and a new power cord or plug adaptor is all you need. I do not know how well regulated the Chinese power system frequency is but most countries regulate their mains frequency pretty well (better than 0.5%), voltage variations tend to be more common than frequency variations but in most cases 10% is easily achieved. There is no reason to believe that China does not do this well. The printer specs indicate that it will work at between 49Hz and 61.2 Hz. The voltage range is 120 -127v + or - 10% which in reality is 108v to 139.7v which is a big range. Some power converters provide voltage regulation at a higher cost and if you are concerned that may be the way to go. There are no other implications. Tony |
Thread Tools | |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Thread Starter | Forum | Replies | Last Post |
HP LaserJet Printer Jams | steveinflorida | Printers | 0 | December 18th 04 09:45 PM |
LaserJet 1320 or Color LaserJet 2550L? | DC | Printers | 0 | October 31st 04 04:50 PM |
Help me kill the ZOMBIE LASERJET 6L!!! | Matt Shepherd | Printers | 0 | October 19th 04 04:18 PM |
OT - China and software piracy | George Macdonald | General | 2 | April 10th 04 03:12 PM |
Intel: China PC Market Overtaking U.S. | Dionaea muscipula | Intel | 0 | October 18th 03 01:02 AM |